BMXMS - 1020/1035/2830 DEVELOPER, 5R523
- MSDS: BMXMS
- Manufacturer: XEROX CORP
- Product Name: 1020/1035/2830 DEVELOPER, 5R523
- National Stock Number: 6810-00N027738
Product Identification
Product ID:1020/1035/2830 DEVELOPER, 5R523
MSDS Date:03/27/1990
FSC:6810
NIIN:00N027738
MSDS Number: BMXMS
Responsible Party
ROCHESTER, NY 14644-1877
US
Emergency Phone: 716-422-2177/716-422-1230 (TRANS)
Info Phone: 800-828-6571
Cage: 0E6G9
Contractor
Telephone: 800-828-6571/716-422-2177
Cage: 26921
Ingredients
TONER CONSISTINGS OF INGREDIENTS 6-10
RTECS: 9999999ZZ
STYRENE/ACRYLATE POLYMER
CAS: 25213-39-2
Fraction By Weight: 60-65%
ACRYLIC RESIN
CAS: 26299-47-8
Fraction By Weight: 20-25%
CARBON BLACK
CAS: 1333-86-4
RTECS: FF5800000
Fraction By Weight: 10-15%
OSHA PEL 3.5 MG/M3
ACGIH TLV: 3.5 MG/M3
PROPENE POLYMERS; (POLYOLEFIN)
CAS: 9003-07-4
RTECS: UD1842000
Fraction By Weight: <5%
SILICON DIOXIDE, AMORPHOUS; (AMORPHOUS SILICA)
CAS: 7631-86-9
Fraction By Weight: <1%
CARRIER CONSISTINGS OF INGREDIENTS 2-4
RTECS: 9999999ZZ
Fraction By Weight: >95%
IRON. PEL & TLV AS FE*2O*3
CAS: 7439-89-6
RTECS: NO4565500
Fraction By Weight: >70%
OSHA PEL 10 MG/M3 TDUST
ACGIH TLV: 5 MG/M3 FUME
ZINC. PEL & TLV AS ZINC OXIDE
CAS: 7440-66-6
RTECS: ZG8600000
Fraction By Weight: 15-20%
OSHA PEL 5MG/M3;10 MG/M3 STEL
ACGIH TLV: 5MG/M3;10 MG/M3 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
NICKEL
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: 5-15%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3
Hazards
LD50 LC50 Mixture:LD50:(ORAL,RAT)>5 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:MINIMAL RESPIRATORY TRACT IRRITATION
MAY OCCUR AS WITH EXPOSURE TO LARGE AMOUNTS OF ANY NON-TOXIC DUST.
IN XEROX SPONSORED CHRONIC INHAL STUDY IN RATS USING SPECIAL TEST
TONER, THERE WERE NO LUNG CHAN GES @ ALL IN THE LOWEST EXPOS LEVEL
(1MG/M3), MOST RELEVANT LEVEL TO POTNTL HUMAN EXPOS. VERY SLIGHT
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NICKEL IARC GROUP 2B; NTP GROUP 2.
Effects of Overexposure:HLTH HAZ:DEGREE OF FIBROSIS WAS NOTED IN 25% OF
ANIMALS @ MIDDLE EXPOS LEVEL (4MG/M3) WHILE SLIGHT DEGREE OF
FIBROSIS WAS OBSERVED @ HIGHEST EXPOS LEVEL (16 MG/M3) IN ALL
ANIMALS. FINDINGS ARE ATTRIBU TED TO "LUNG OVERLOADING", A GENERIC
RESPONSE TO EXCESSIVE AMT OF ANY DUST RETAINED IN LUNGS FOR PRLNG
(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE WHEN USED AS DESCRIBED BY
PRODUCT LITERATURE.
First Aid
First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MIN. SKIN: WASH WITH
SOAP AND WATER. INHAL: REMOVE FROM EXPOSURE. INGEST: DILUTE STOMACH
CONTENTS WITH SEVERAL GLASSES OF WATER.
Fire Fighting
Extinguishing Media:WATER, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . AVOID INHALATION OF SMOKE.
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:IF SPILLED, SWEEP UP OR VACUUM.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE.
Other Precautions:AVOID PROLONGED INHALATION OF EXCESSIVE DUST.
Exposure Controls
Respiratory Protection:NONE REQUIRED WHEN USED AS INTENDED IN XEROX
EQUIP. USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN .
Ventilation:NONE REQUIRED WHEN USED AS INTENDED IN XEROX EQUIPMENT.
Protective Gloves:NONE REQD WHEN USED AS (SUPP DATA)
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: INTERVAL. SPECIAL TEST TONER WAS 10 TIMES MORE
RESPIRABLE THAN COMMERCIALLY AVAILABLE XEROX TONER TO COMPLY WITH
EPA TESTING PROTOCOL AND WOULD NOT FUNCTION PROPERLY IN XEROX
EQUIPMEN T. PROT GLOVES: INTENDED IN XEROX EQUIPMENT.
Chemical Properties
HCC:N1
Spec Gravity:APPROX 5
Appearance and Odor:BLACK GRANULAR/FAINT ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:PRODUCTS OF COMBUSTION MAY BE TOXIC.
AVOID BREATHING SMOKE.
Disposal
Waste Disposal Methods:NO SPECIFIC WASTE DISPOSAL METHOD REQUIRED.
DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.